✉ repository@umpar.ac.idOpen Access Institutional Repository LoginCreate accountAdvanced search

STUDI EKSPERIMENTAL PERBANDINGAN ENERGI LUARAN PIEZOELEKTRIK DALAM RANGKAIAN SERI DAN PARALEL

FEBRIAN, 221180008 (2024) STUDI EKSPERIMENTAL PERBANDINGAN ENERGI LUARAN PIEZOELEKTRIK DALAM RANGKAIAN SERI DAN PARALEL. Other thesis, UNIVESITAS MUHAMMADIYAH PAREPARE.

[thumbnail of Sampul] Image (Sampul)
SAMPUL_221180008_FEBRIAN_ELEKTRO.pdf - Cover Image

Download (66kB)
[thumbnail of Pendahuluan] Text (Pendahuluan)
PENDAHULUAN_221180008_FEBRIAN_ELEKTRO.pdf - Supplemental Material

Download (1MB)
[thumbnail of BAB/Isi] Text (BAB/Isi)
ISI_221180008_FEBRIAN_ELEKTRO.pdf - Supplemental Material

Download (1MB)
[thumbnail of Lampiran] Text (Lampiran)
LAMPIRAN_221180008_FEBRIAN_ELEKTRO.pdf - Supplemental Material

Download (756kB)
[thumbnail of Artikel] Text (Artikel)
JURNAL_FEBRIAN_221180008.pdf - Published Version

Download (621kB)

Abstract

Piezoelectric sensors are devices that can generate electrical energy from mechanical pressure or vibration, but the energy generated is relatively small and highly dependent on the strength and consistency of the pressure applied. This study aims to determine the most optimal configuration of piezoelectric sensor circuits in generating voltage, current, and electrical power so that it can be determined whether piezoelectric sensors can be used as the main energy source. Tests were carried out on one piezoelectric sensor with varying loads as a reference in the experiment, then comparing series and parallel configurations, with varying numbers of sensors. In series and parallel configurations, tests were carried out on 2 to 9 sensors, while the parameters observed included voltage, current, and maximum, minimum, and average power generated from each configuration. Tests were carried out by applying mechanical pressure in the form of blows to each circuit. The test results showed that testing one sensor with a load of 330 Ω produced a voltage (1,14–1,69 V), and a current (3,42–5,09 mA); while the series circuit configuration produced a maximum power of (3,75 mW), a minimum (1,48 mW), and an average (2,404 mW); Meanwhile, the maximum power of the parallel circuit configuration is (3,57 mW), minimum (0,85 mW), and average (1,14 mW). The experimental results show that the series circuit configuration is more effective in producing electrical energy than the parallel configuration, although the energy produced is still relatively low.

Item Type: Thesis (Other)
Uncontrolled Keywords: Piezoelectric Sensor; Electrical Energy; Pressure; Circuit Configuration; Measurement
Subjects: Sains dan Teknologi
Divisions: Fakultas Teknik > Teknik Elektro
Depositing User: Saeqal Firdaus
Date Deposited: 29 Oct 2026 00:25
Last Modified: 29 Oct 2026 00:25
URI: https://repository.umpar.ac.id/id/eprint/1227

Actions (login required)

View Item
View Item